Find Gas Exhaust Fan, Gas Vent Fan, Induced Draught Fan on Industry Directory, Reliable Manufacturer/Supplier/Factory from China.

Home > Products > AC Fan > AC Cooling Fan > 22060 AC The Gas Exhaust Fan

22060 AC The Gas Exhaust Fan

Packaging: 
40piece/carton
Productivity: 
100000
Brand: 
kungpeng
Transportation: 
Ocean,Land,Air
Place of Origin: 
chain
Supply Ability: 
0~1000000
Certificate: 
UL/CUL/TUV/CE/CCC

Basic Info

Model No.: FS22060

Product Description

Ac fan working principle relies on ac power to drive, voltage will be positive and negative alternating, completely independent of circuit control, generate magnetic field. The power frequency is fixed, and the magnetic pole change speed produced by the silicon steel sheet is determined by the power frequency. The higher the frequency, the faster the magnetic field is switched, the faster the speed will be in theory. However, the frequency should not be too fast, too fast will cause difficulties in starting.

FS22060 is often used in Household exhaust and cooling,it is suit for big kitchen fitting cooling,if you want it fasting,you should make choice of the ball bearing and copper wire motor fan.



FS22060 copper line AC axial fan detail:


Fs20060 Ac Axial FanFs20060 Ac Axial FanFs20060 Ac Axial FanFs20060 Ac Axial FanFs20060 Ac Axial FanFs20060 Ac Axial Fan


Fs20060 Ac Axial Fan



Fs20060 Ac Axial Fan




Fs20060 Ac Axial Fan



Fs20060 Ac Axial Fan



Fan 1

System impedance of equipment

In accordance with the internal construction of the equipment to be called. The resistance will appear when passing air through the equipment

This will cause reduction of stationary pressure during the ventilation and is called the system impedance.

Consequently,it becomes necessary for us to give stationary pressure value higher than the impedance for performing ventilation to the equipment system impedance can be given using the following formula:

Δ P=Reduced pressure(mm-H2O)

Q=Air Volume(m3/min)

Δ P=KQn K5 Constant

N=index to be determine by air flow

N=1:laminar flow

N=2:Turbulent flow (Normally n=2)

The constant K here cannot be determined unless measure it by physically equipment.


Fan 3


Selection of the Fan

The selection of fan is done in according with following steps:

a) .Estimate the heat value (kw)of the heat source.

b) Determine the allowable temperature rise value Δ T

c) Assume the approximate ventilation volume in according with Formula(1)

d) Assumption of system impedance based on the ventilation of internal equipment of past data

e) Decide on the fan by referring to the Characteristic curve in Figure 2 from your catalog

f) Determine the adaptability of the fan by physically installing it is the equipment and measure the air temperature rise value Δ T or draft volume Q. if draft volume Q is insufficient, It is caused by the high system impedance , so it advisable to replace it with a higher quality fan


Measurement and measures against the Noises

Measurement of Noises

Measure it at 1.0 meters from the machine plane (at the central line of the air inlet )according to JIS-B8330(A characteristics)

Measures against Noises.

Although our fan motors are designed with special consideration of noises,sometime,it still can be affected by the user` s machine design to a large extent , so our attention is drawn to the following points:

a. Keep some distance between the object to be cooled and the inlet of the far. (Figure a -1)

b. When fittings are used ,pay attention not to cross each other with a spring .(Figure b -1)

c. When more than two fans are used, please keep then apart.(Figure c -1)

d. When finger guide is used, please keep it separated from the fan (We have kept some for this purpose.)


Technical information of fan motor

Measurement of air volume and static pressure

In our company we have been measuring the air volume using the multi - nozzle chamber air volume measuring device of automatic recording type,which is in conformity with the highly reliable AMCA specifications(USA).

The error rate is below 1% theoretically.(based on AMCA),Also it is possible to measure the characteristics of the suction side as well as the blowing side ,( 54144285, 54144272, 54142882, 54141828, 54141732, 54140759,the values in catalog show the characteristics of the blowing side .)


Fan 2




Contact us if you need more details on Gas Exhaust Fan. We are ready to answer your questions on packaging, logistics, certification or any other aspects about Gas Vent Fan、Induced Draught Fan. If these products fail to match your need, please contact us and we would like to provide relevant information.

Product Categories : AC Fan > AC Cooling Fan